ijaers social
facebook
twitter
Blogger
google plus

International Journal of Advanced Engineering, Management and Science


Study of 12KW Solar Office System at Atomic Energy Centre Chittagong

( Vol-2,Issue-7,July 2016 )

Author(s): M. N. Islam, A. Rahman, H. Akhter, M. Begum, Y. Mawla, M. Kamal



Total View : 880
Downloads : 164
Page No: 1033-1036
ijaems crossref doiDOI:

Keywords:

Solar Cell/Panel, Solar MPPT, Solar Inverter, Battery Bank and Solar System.

Abstract:

In this article, A Study of 12KW Solar Office System (SOS) at Atomic Energy Centre Chittagong (AECC) has been presented. The SOS has total of 12KW install capacity (panels) with 220V AC, 50 Hz, Single phase (off-grid) power supply consists of forty eight Solar Panels (250W, 30V, 6.25A), three Solar Charge Controllers with MPPT (48V, 60A), three Inverters (5000VA, 48V), a Battery Bank of 1531AH total twenty four batteries (12V, 130AH) and required accessories (mounting structures, cables and clamps, solar breakers, output breakers, energy meters etc.). This study has been completed according to notification of award for supply, installation, testing and commissioning of solar energy setup under establishment of atomic energy centre project at sholashoar, East Nasirabad, Chittagong.

Cite This Article:
Show All (MLA | APA | Chicago | Harvard | IEEE | Bibtex)
Share: